In Brief
Façade cladding is a covering system mounted on a building's exterior surface via a substructure that protects the wall from rain, wind and sun. In ventilated systems, where an air gap is left between the cladding and the wall, moisture buildup is reduced and the insulation stays dry. The material, substructure and junction details are determined during the site survey according to the building.
- Residential façades, eaves and parapet cladding
- Ventilated substructure option
- Same color and material line as the roof
- Care taken with joint and waterproofing details
Table of Contents
What is façade cladding and what is it for?
Façade cladding is a system that covers a building's exterior surface for both appearance and protection. It protects the wall from rain, wind, sunlight and temperature changes, and gives the building a renewed, tidy look. When designed in line with the roof, it also strengthens the building's overall coherence.
An important type of façade cladding is the ventilated (rainscreen) façade. In this system, the cladding is separated from the wall by an air gap. The gap lets the small amount of water entering through the cladding joints drain away and evaporate; it also reduces wind-driven water being pushed toward the wall. Because the insulation and the wall stay dry, the risk of moisture buildup and mold is lower.
Difference between a ventilated façade and an external thermal insulation system (ETICS)
The two systems are often confused; their purposes and ways of working differ.
| Feature | Ventilated façade cladding | External thermal insulation system (ETICS) for façades |
|---|---|---|
| Structure | Cladding panel mounted on a substructure; air gap behind | Thermal insulation board is bonded to the wall, then plastered and painted |
| Moisture management | Thanks to the air gap, water droplets drain and evaporate | If moisture gets under the plaster layer, it is harder to drain |
| Appearance | Panel, sheet or metal cladding; jointed, geometric look | Plastered, single-piece surface |
| Cladding replacement | A damaged panel can be replaced individually | Damage requires repair of the plaster surface |
Which one is suitable depends on the building's current condition, its need for thermal insulation and your expectations. At Rızaoğlu Çatı, in cladding work we assess the substructure, the joint details and whether insulation is needed together with you during the site survey.
Areas of application
- Residential façades: Partial or full-surface cladding on villa and apartment façades.
- Eaves and parapet cladding: Closing off roof edges and parapet walls with clean lines.
- Façade renewal: Renewing aged surfaces or surfaces with deteriorated paint with a new cladding.
- Open-area structures: Cladding the roofs and walls of pergolas, garages and similar open-area structures.
- Integrated roof-façade designs: Façade cladding that continues in the same metal and color as a standing seam roof.
You can see our residential façade project in Konya on the project page and find more photos in the façade cladding gallery.
Cladding material options
Painted galvanized or aluminum sheet, aluminum composite panels, fiber cement boards, and wood or wood-look panels are commonly used for façade cladding. Each material differs in weight, maintenance needs, appearance and reaction to fire. Which material suits your building is determined during the site survey, taking into account building height, the existing surface, budget and harmony with the roof.
If you are using standing seam on the roof, choosing the same metal and color for the façade or eaves cladding makes the roof and façade look like a single whole. For the roof side, see the standing seam roof systems page.
Advantages and points to watch
Advantages
- Protection against external factors: Rain, wind and sun do not reach the main wall directly.
- Renewed look: An aged façade gets a new look without needing plaster and paint renewal.
- Contribution to thermal and moisture management: When insulation is used behind the cladding, thermal and moisture management improves.
- Piece-by-piece repair: In most systems, a damaged panel can be replaced on its own.
Points to watch
- Fire behavior: Unsuitable façade materials can cause fire to spread across the exterior surface. The material's reaction-to-fire class and the fire regulation requirements for the building height must always be checked.
- Keeping the air gap clear: In a ventilated system, if the gap is blocked the system does not serve its purpose; screens that keep rodents and insects out are fitted at the openings.
- Around windows and doors: These areas are sensitive to water leaks; details are completed with waterproofing in mind.
- Thermal expansion: In Konya the difference between summer heat and winter frost is large (Turkish State Meteorological Service (MGM) records: highest 40.9 °C, lowest -28.2 °C); an expansion joint allowance must be left for the panels' expansion.
- Substructure and fasteners: Corrosion-resistant material should be chosen, and connection points should be made with attention to waterproofing.
Installation steps
- Site survey and measurements: The façade's existing surface, moisture condition and dimensions are taken.
- Cladding and substructure selection: The material, color and substructure type are determined; whether insulation will be used is decided.
- Surface preparation: Loose plaster, moisture and cracks are checked and repaired if necessary.
- Substructure installation: The supporting profiles are fixed to the wall to measure, straight and level.
- Insulation and protective layer: If it will be used, the insulation material is installed; the air gap behind the cladding is preserved.
- Cladding installation: Panels or boards are fixed to the substructure, leaving an expansion joint allowance.
- Corner, eaves and parapet junctions: The junctions are waterproofed.
- Around windows and doors: The surround profiles and water-collection details are completed.
- Cleaning and inspection: The surface is cleaned, and the connections and joints are checked together.
Maintenance and extending service life
- Wash the surface with soft water and a suitable detergent at least once a year; do not use abrasive materials.
- After storms and hail, visually check the panel connections and joint seams.
- Make sure the air gap inlets and outlets are not blocked by leaves, dust or bird nests.
- Have a scratched surface or one with damaged paint repaired without delay.
- Check the gutters, downpipes and cladding connections on the façade together; water leaks often start there.
Factors affecting cost
- Area of the surface to be clad and the building's height (need for scaffolding or a platform)
- Type, thickness and color of the cladding material
- Type of substructure and flatness of the surface
- Whether insulation will be used
- Number of details such as corners, windows, eaves and parapets
- Whether the existing cladding must be removed or the surface repaired
The exact figure is given in a written quote after the site survey. To get a quote, you can fill out the form.