Skip to content

INTERFIKS FIXGROUT EPO F

Product code: FIXGROUT EPO F

FIXGROUT EPO F is an epoxy-based grout mortar with a flowable consistency. It is used in heavy machinery installations, on machine foundations subject to high dynamic loads, and on gantry and tower crane rails; it is self-leveling.

Product code
FIXGROUT EPO F
Stock status
Available to order
Ask on WhatsApp

Prices are not shown in the catalog; you can request a quote for the product.

Share

  • Based in KonyaWe serve customers in Karatay, Konya
  • Founded in 1998Rızaoğlu Çatı
  • Phone and WhatsAppContact us directly about products and installation
  • Bulk quoteOne form for multiple products

Product Description

FIXGROUT EPO F is an epoxy-based, flowable grout mortar. It is used in heavy machinery installations, on machine foundations exposed to high dynamic loads, and on gantry and tower crane rails; it is self-leveling. To determine and obtain the right product for your project, you can talk to Rızaoğlu Çatı.

About the Product

FIXGROUT EPO F is an epoxy-based, solvent-free, three-component, high-strength, self-leveling grout mortar containing special-graded quartz aggregate.

Advantages

  • Self-leveling
  • Does not require a primer
  • Has high chemical resistance
  • Has high compressive, flexural and tensile strength
  • Protects reinforcement excellently against corrosion through its barrier effect
  • Provides excellent adhesion between old and new concrete
  • Solvent-free

Areas of use

  • In very heavy machinery installations
  • On machine foundations that will be exposed to high dynamic loads
  • In repairs on the beams and legs of gantry and tower cranes
  • In bridge bearings
  • In fixing steel columns to the foundation
  • In repairing wide cracks found in structures and slabs
  • In bonding different materials such as concrete, stone and metal
  • As an adhesive for planting starter bars into horizontal surfaces or for anchoring and fixing reinforcement

Technical Specifications

FeatureValue
ColorYellowish
Physical state3-Component
Mortar density1.70 ± 0.05 g/cm³
Application temperatureBetween +5 °C and +35 °C
Application thicknessmax. 30 mm
Pot life30 min.
Time to put into service24 hours
Service temperatureBetween +15 °C and +80 °C
Compressive strength (EN 12190)> 50.0 N/mm² (1 day) > 75.0 N/mm² (28 days)
Flexural strength (EN 12190)> 15.0 N/mm² (1 day) > 20.0 N/mm² (28 days)
Bond strength to concrete (EN 1542)> 3.0 N/mm²
PackagingComponent A: 3 kg tin can
Component B: 1.7 kg tin can
Component C: 15.3 kg tin can
ConsumptionAbout 1.7 kg/m² is used per 1 mm thickness.
Shelf life and storageStore in a dry, moisture-free place. Shelf life is 12 months. The lids of opened but unused containers must be closed tightly again.

Values are summarized from the manufacturer's technical data sheet; before application, the current technical data sheet and the Safety Data Sheet (MSDS) should be used as the basis.

Application

Surface preparation

  • The concrete to be treated must have a compressive strength of at least 225 kg/cm², must have been cured for 28 days, and must contain no more than 5% moisture at the end of this period.
  • As with all epoxy applications, the quality of surface preparation directly affects system durability and performance.
  • The surface must be completely cleaned of dirt, dust, oil, curing compounds, paint, and lifted, detached and poorly bonded particles.
  • Metal surfaces must also be cleaned of rust.

Mixing

  • The packages must be used whole, without dividing them and without changing the mixing ratios.
  • Add Component B to Component A and mix with a drill for 3 - 5 min. until a homogeneous mix is obtained.
  • Then add Component C and mix for another 3 - 5 min. to obtain a homogeneous mix.

Application method

  • Immediately after mixing, the mortar must be poured onto the prepared area from one side only, so that the flow goes in the direction of the shortest distance.
  • Pouring must continue without interruption from a point at the lowest level until the area to be grouted is completely covered.
  • An air vent must be left at the highest level so that the air can escape.
  • The application thickness must be at least 4 mm and no more than 50 mm in a single layer. If the application exceeds 50 mm, it must be done in 2 layers. Wait 6 hours before applying the second layer.

Points to Note

  • Do not apply at air temperatures below 5 °C or above +30 °C.
  • Never mix by hand or with a trowel.
  • Before removing the formwork, wait for the mortar to reach its initial cure.
  • At low temperatures the working time lengthens; at high temperatures it shortens
  • Must be protected from water for 24 hours.

Application Solutions

  • Anchoring and Installation Applications

Product information is based on information published by the manufacturer Interfiks.

Products That Can Be Used with This Product

Suggestions we picked from the accessory and insulation groups. Ask our team about compatibility and quantities.

Similar Products

Request a Quote and Site Survey for This Product

Send us the quantity and installation details, and our team will contact you to plan the quote and site survey process.

  1. 1 Send Your Request
  2. 2 We'll Call You
  3. 3 Site Survey and Quote