- Author: Rızaoğlu Çatı Editorial Team
- Published:
- Updated:
- 6 min read
Table of Contents
- Where should a roof window be placed?
- What dimensions are used for size and height?
- At what pitches and with which coverings can it be installed?
- How are waterproofing and condensation handled?
- Are blinds, shutters, and awnings necessary?
- What is looked at regarding zoning and permits?
- Before you decide
- FAQ
Short answer: A roof window is placed according to the use of the room and the roof pitch; the VELUX Türkiye catalog recommends that the lower edge of the window be 90-120 cm above the floor and that the glazed area be at least 16% of the room's floor area. The pitch range varies by product; for waterproofing, a system consisting of flashing, an insulation collar, and a drainage gutter is used, and it is not solved with silicone alone.
A roof window is a product that provides both daylight and ventilation, so its location, size, and installation detail should be considered together. If the window is at the wrong height, the view and use become difficult; if waterproofing is incomplete, there is a risk of leaks. The dimensions and ranges in this article are based mainly on the VELUX Türkiye product catalog; these are manufacturer recommendations, should not be regarded as a general regulatory provision, and each product's current installation guide should be consulted. For a short definition of the term, see the roof window entry in the roofing glossary.
Where should a roof window be placed?
The starting point of placement is how the room will be used. The same lighting need does not apply to every room: for a work or reading corner, balanced light throughout the day is sought, while in a bedroom a dim and calm atmosphere may be preferred. For this reason, the window should be planned knowing the position of the furniture. If the bed, desk, or wardrobe falls right under the window, both access and opening the ventilation sash become difficult.
Orientation also affects the quality of light. In general, south-facing roof surfaces receive more sun throughout the day; although this is an advantage for daylight, it can increase heating inside in summer. On north-facing surfaces the light is more balanced. External accessories can be used to control heating; details are discussed below. It should also be kept in mind that obstacles such as chimneys and antennas on the roof can make snow shedding harder, and the window position should be assessed together with these protrusions.
The position on the roof surface also determines the waterproofing details. If more than one window will be used, placing them in line and at regular intervals simplifies the appearance. If the window falls too close to a chimney base, a valley, or the ridge, these details can affect each other and make installation harder. BMI Türkiye lists faulty installation at valleys, chimney-wall junctions, and roof window flashings among the known sources of sealing problems; for this reason, it is important to position the window at a reasonable distance from other details and to plan the installation together with the covering work.
What dimensions are used for size and height?
The VELUX catalog recommends that, for optimum comfort, the glazed area be at least 16% of the room's total floor area; the lighting need varies with the room's use. This is a manufacturer recommendation. For height, the lower edge of the window is described as 90-120 cm above the floor and the upper edge as between 185 and 220 cm. As the roof pitch decreases, a longer window needs to be chosen; the aim is for the window to sit at a height similar to that of a vertical window.
| Criterion | Value in the catalog | Note |
|---|---|---|
| Glazed area | At least 16% of the room floor area | Manufacturer recommendation; varies with the use of the room |
| Lower edge height | 90-120 cm above the floor | Related to seated and standing eye level |
| Upper edge height | 185-220 cm above the floor | As the pitch decreases, a longer window is chosen |
| Harmony with a vertical window | Positioning at a similar height | Provides visual unity with the windows on the façade |
Keeping the lower edge more than 90 cm above the floor is also consistent with the guardrail threshold in the zoning regulations; this is returned to below.
At what pitches and with which coverings can it be installed?
“A roof window fits any pitch” is a common misconception. In the catalog, the pitch range of most models is given as 15° to 90°; in some series this range is 15° to 55°. The waterproofing flashing is chosen according to the covering type, and the ranges of the flashing types also vary: the catalog shows 15°-90° for three types and 20°-90° for one type. On low-pitched roofs, the product's own limit and the manufacturer's recommendation are decisive; considering that the pitch also affects the covering, the article how to choose roof pitch gives the background to this decision.
- The pitch range of the window model should be checked.
- A flashing type suitable for the roof covering should be chosen.
- If the pitch is near the limit or the covering is unusual, the manufacturer should be consulted.
How are waterproofing and condensation handled?
A roof window's waterproofing is not provided by silicone alone. The manufacturer's system consists of flashing, an insulation collar, and a drainage gutter: the standard flashing set includes an insulation collar and a drainage gutter; the set with an added insulation frame aims to reduce heat loss and thermal bridging; the set that also includes a vapor barrier is designed to prevent condensation in the roof. These claims belong to the manufacturer. For the place of waterproofing and the vapor barrier in the roof layers, see the article roof insulation layers and vapor barrier; the layers around the window should be consistent with this general arrangement.
When adding a window to an existing roof, the covering around the window needs to be opened and rearranged together with the flashing. For this reason, the job should not be considered independent of the covering and underlay work; which layers will be cut, where they will join, and how water will be directed around the window should be clarified before installation.
Fogging of the glass indoors is mostly due to excess humidity. According to manufacturer information, the solution is to make ventilation a habit and to reduce moisture sources; even opening the window briefly can be effective. Keeping the ventilation sash closed during snowfall is also recommended, because warm air escaping from a window left open can melt the snow on top of the window.
Are blinds, shutters, and awnings necessary?
Because a roof window is a surface that receives direct sun, it can heat the interior in summer. The VELUX catalog states that external accessories that block solar heating can noticeably lower the indoor temperature; this is a manufacturer claim, and the effect varies with orientation, glazing, and use. Interior blinds adjust light and privacy of view, but cannot stop heat outside the glass. External shutters and awnings try to cut off heating before it reaches the glass.
There are practical criteria for choosing accessories: Is the window easy to reach, will the control be manual or motorized, is blackout or heat control the priority? If the answers to these questions are considered together with the window placement, installing accessories later also becomes easier.
What is looked at regarding zoning and permits?
According to the current consolidated text of the Regulation on Zoning for Planned Areas, roof windows may protrude above the roof covering in a size and form the administration deems appropriate (Article 40/5). A guardrail is mandatory if the window opening is less than 0.90 m above the floor slab level (Article 38/1); keeping the lower edge of the roof window more than 90 cm above the floor coincides with this threshold. Windows must also comply with the Regulation on Energy Performance of Buildings (BEP) and TSE standards (Article 39/3).
Opening a window in an existing roof can mean a change in the roof covering and the appearance. Whether such work requires a permit varies with the condition of the building, whether it is in a planned or unplanned area, and the administration's practice; the relevant municipality's zoning department should be consulted before starting. For apartment building roofs, since the roof counts as a common area, the management plan and unit owners' assembly decisions also come into play.
Before you decide
When choosing a roof window, the order generally goes like this: first the room's light and ventilation need is determined, then the window's position and height are settled according to the furniture plan, then a model and flashing type suitable for the pitch and covering are chosen. For information about the products, you can look at the roof window products and the VELUX brand page. For planning the installation together with the insulation and covering work, see the roof window and solar panel solutions page. You can reach us for a site survey through the quote page.
FAQ
How large should a roof window be relative to the floor area of the room?
The VELUX Türkiye catalog recommends that the glazed area be at least 16% of the room's total floor area for optimum comfort. This is a manufacturer recommendation, not a regulatory provision. The light required may vary with the use of the room, its orientation and the roof pitch.
How many cm above the floor should the bottom edge of a roof window be?
The catalog describes a range of 90-120 cm above the floor for the bottom edge of the window and 185-220 cm for the top edge. As the roof pitch gets lower, the window needs to be taller. Keeping the bottom edge above 90 cm is also consistent with the guardrail threshold in the zoning regulation.
Can a roof window be installed on any roof pitch?
No. In the catalog, the pitch range of most models is between 15° and 90°, and for some series between 15° and 55°; the ranges for flashing types also differ. For low-pitched roofs, the manufacturer's current installation guide should be consulted and, if necessary, the manufacturer should be asked.
Can a roof window be waterproofed with silicone?
The manufacturer's system consists of a flashing, an underlay collar and a drainage gutter; it is not described as a detail to be solved with silicone alone. The flashing type is chosen according to the roof cladding, and installation should be carried out according to the manufacturer's current guide.