- Author: Rızaoğlu Çatı Editorial Team
- Published:
- Updated:
- 6 min read
Table of Contents
Short answer: Roof pitch is chosen first according to the manufacturer's minimum limit for the covering, then according to climate, snow, and architecture. In planned areas, the zoning regulation does not give a fixed percentage; the pitch is determined by the authority, taking the material, locality, and climate into account. For tile, the minimum varies by type; for standing seam, about 3° appears in manufacturer examples. The exact value is settled through the manufacturer's data sheet, the project, and the municipality.
Roof pitch is not a single measurement but a decision that affects the covering, water flow, snow, wind, and appearance at the same time. If the pitch is too low, the covering may fall below the manufacturer's limit; if it is too high, the ridge height grows, and snow and ice sliding becomes a safety issue. This article brings together the factors that determine pitch, the minimum-limit examples found in the sources, and the zoning framework. Since manufacturers' pitch and overlap limits change by product and guide version, the manufacturer's current installation guide should be consulted for each product.
How are degrees and percent read?
Pitch is expressed in two units, and mixing them up is the most common mistake. Degrees are the angle the roof surface makes with the horizontal; percent shows how many units it rises per 100 horizontal units. The conversion is a trigonometric calculation; the values below are derived from this calculation.
| Degrees | Approximate percent | Note |
|---|---|---|
| 3° | %5,2 | Minimum limit of some metal standing seam manufacturers |
| 10° | %17,6 | Example limit for tile reduced with an additional sub-roof |
| 18,3° | %33 | Ratio in the unplanned-area rule |
| 30° | %57,7 | Pitch at which the snow coefficient begins to decrease in the standard |
| 45° | 100 percent | Horizontal and vertical are equal |
In Türkiye, a tile manufacturer divides roofs into pitch classes: flat roof less than 6 percent, low-pitched 6 to 16 percent, medium-pitched 20 to 35 percent, steep 45 percent and above. Classes may be named differently by different manufacturers; as a source, this is one guide's example. For the term, see the roof pitch entry in the glossary.
What factors determine pitch?
- Covering type: Each covering has a minimum pitch defined by the manufacturer; below this limit, the waterproofing, joints, and overlaps are reconsidered.
- Climate and snow: The snow load on the roof decreases as the pitch increases; this topic is covered under a separate heading below.
- Precipitation: Annual precipitation in Konya is about 320-330 mm (Turkish State Meteorological Service (MGM) and an academic study); in rainy and snowy regions, water and snow drainage becomes more decisive.
- Architecture and zoning: The architectural character of the area, the ridge height, and municipal rules set the upper limit of the pitch.
- Use: Whether the attic will be used and its height are designed together with the pitch; the regulation does not allow independent units to be built in attics.
Minimum pitch examples by covering
The values below are examples found in the sources; all of them are manufacturer or country rules, and for a product to be used in Türkiye, the value in the manufacturer's data sheet should be the basis.
| Coating | Minimum pitch example | Source type |
|---|---|---|
| Zinc double standing seam | 3°; standing seam strip between 3° and 7° | Manufacturer |
| Another metal standing seam product | 3°; generally at least 7° for the substructure | Manufacturer |
| Tile (German rules) | 22°, 35°, and 40° depending on type; in no case below 10° | Trade rule |
| Tile (UK examples) | Between 15° and 30° depending on the product | Manufacturer |
| Tile, with an additional sub-roof | About 10°; 12.5° for trough type | Manufacturer |
| Tile-covered roof in an unplanned area | 33 percent | Regulation |
With tile, the overlap depends on the pitch: a manufacturer in Türkiye states that the lengthwise overlap distance is taken from the table in the product catalog according to the pitch, and that above a certain pitch the tiles are required to be fixed with screws or wind clips. A British manufacturer, on the other hand, says that increasing the overlap does not always allow going below the tile's minimum pitch; for long rafters, an additional 1° of pitch is recommended each time the length exceeds the manufacturer's maximum by 0.5 m. For the choice of covering, you can read the tile roof systems and standing seam roof systems pages and the article standing seam and tile comparison.
What does the zoning regulation say about pitch?
A common misconception is that the zoning regulation limits roof pitch to 33 percent. The current text of Article 40 of the Regulation on Zoning for Planned Areas does not state a fixed percentage. It says that roof pitches are to be determined with the approval of the relevant authority, taking into account the roofing material to be used, the architectural character of the area, and climate conditions. The pitch is calculated from the eaves edge, and the roof cannot be set on a parapet. The plane of the roof covering is determined provided that the ridge height does not exceed 5.00 m. Roof windows, solar energy systems, and mandatory installation spaces may extend above the roof covering to the extent the authority deems appropriate; provided that it stays within the roof pitch and does not affect its silhouette, a photovoltaic panel can also be used as a roof covering. Municipal councils may determine the roof material and color. The roof coverings of registered buildings, monuments, and public-benefit or religious buildings are not subject to these provisions.
The 33 percent ratio appears in Article 53 of the Regulation on Zoning for Unplanned Areas, in the form that tile-covered roofs are to be built at this slope and the character of the surroundings is to be respected. This regulation applies to unplanned areas. A provision on roof pitch in the Konya Metropolitan Municipality Zoning Regulation does not appear in the sources we compiled; for a specific parcel, the relevant municipality's zoning department should be asked. Since the current text of regulatory provisions may change, the latest version should be confirmed with the municipality.
Relationship between pitch and snow load
According to TS EN 1991-1-3, the snow load on a roof is found by multiplying the ground snow load by the roof shape coefficient. For single-pitch and double-pitch roofs, the shape coefficient is 0.8 between 0° and 30°; it decreases linearly between 30° and 60° and is taken as zero at 60° and above. The Konya city center is in Snow Zone II in the national annex of this standard, and the table value for 1000 m is 1.05 kN/m². As the pitch increases, less snow remains on the roof. However, if a snow guard or an eaves parapet prevents the snow from sliding, the coefficient is taken as at least 0.8. The force that sliding snow exerts on the snow guard is also calculated together with the pitch. The standard says that snow overhanging the eaves should also be considered and recommends this especially for places above 800 m; since Konya is at an altitude of about 1000 m, this topic may fall within scope. For details, you can read the article climate when building a roof in Konya and the snow load entry in the glossary.
Increasing the pitch does not solve every problem: the sliding safety of snow and ice, the need for a snow guard, and the ridge height are assessed together. A manufacturer's guide recommends applying snow guards together with a snow retention system at pitches of 45° and above; the layout pattern is determined by the pitch and the ground snow load, and a snow guard is not considered fall protection.
What should be considered if a low pitch is needed?
If the pitch must remain low for architectural or zoning reasons, the options vary by covering. In German trade rules, when the pitch falls below the one regarded as safe from experience for a covering, a sub-roof with additional waterproofing is required. In the UK, a manufacturer states that a bituminous sub-roof solution allows concrete, slate, and clay tile types to be laid down to 10° and trough tile down to 12.5°. The minimum limits for metal standing seam may be defined as lower than for tile. In every case, manufacturer approval and the project are the basis; for comparison, you can use the standing seam roof or tile roof page and the roof selection wizard.
Before you decide
Choosing the pitch means reading the covering, climate, supporting structure, and zoning information together. The following can be prepared before the site survey:
- The minimum pitch and overlap value in the manufacturer's data sheet for the selected covering.
- Whether the parcel is in a planned or unplanned area, and the relevant municipality's roof rules.
- The building's altitude and snow zone, and the need for snow guards.
- The ridge height and the suitability of the existing supporting structure for the pitch.
For a preliminary area and material estimate, the roof calculator can be used; the pitch decision is settled at the site survey, with information from the project designer and the product manufacturer.
FAQ
Does the roof pitch have to be 33 percent?
No. Thirty-three percent is a ratio given for tile-covered roofs in the Regulation on Zoning for Unplanned Areas. The Regulation on Zoning for Planned Areas does not specify a fixed percentage; the pitch is determined by the authority, taking the material, locality and climate into account. For a specific parcel, the relevant municipality should be consulted.
What is the minimum pitch of a standing seam roof?
One titanium zinc standing seam manufacturer gives the lower limit as 3° (about 5.2 percent); between 3° and 7° a standing seam sealing tape is required. Another metal standing seam manufacturer also gives 3° but generally recommends at least 7° for the substructure. The current installation guide of the product to be used should be consulted.
What is the minimum pitch in degrees for a tile roof?
There is no single value; it varies with the tile type and the manufacturer. German trade rules give values such as 22°, 35° and 40° depending on the type, and British examples show between 15° and 30°. With an additional sub-roof, some manufacturers offer solutions that go down to around 10°. In Türkiye, the value on the product data sheet should be used as the basis.
Does the snow on a roof decrease as the pitch increases?
According to the standard, yes: the roof shape coefficient is 0.8 up to 30°, decreases between 30° and 60°, and is taken as zero at 60° and above. If there is a snow guard or an eaves parapet, the coefficient is taken as at least 0.8. The calculation must be made by a licensed engineer.