Short answer: Yes. Winters in Konya are cold, the daytime temperature swing is large, and about a hundred days of frost occur per year; in the standards, the provincial center is in Snow Zone II. These data affect the cladding, pitch, layer arrangement, connections and snow/ice measures. Climate alone does not determine the roof type, but it is an input that must be taken into account in every decision.
The roof is the part of a building directly exposed to rain, snow, wind and sun. The same system can behave differently in two cities, because the load on a roof depends not only on the material but also on the weather conditions it experiences throughout the year. This article lists Konya's climate data, what they mean for the roof, and the points to look at when deciding. The figures are taken from records of the Turkish State Meteorological Service (MGM) and from standard texts such as TS EN 1991-1-3; on every matter requiring calculation, the final word rests with the project author and the engineer who does the structural calculation.
What does Konya's climate look like in numbers?
According to MGM's Konya statistics covering 1927–2025, the lowest measured temperature was −28.2 °C (January) and the highest 40.9 °C (August). Calculated from monthly values, the annual mean temperature comes to about 11.8 °C and annual precipitation to about 326 mm; since a 1975–2006 study by Selçuk University found 321 mm, it is safe to say “about 320–330 mm.”
MGM places Central Anatolia in the steppe (semi-arid) climate class, with a large day–night temperature difference. Calculated from monthly MGM averages, the difference between the mean maximum and mean minimum temperature is about 9 °C in January, 14.5 °C in August and about 15 °C in September; that is, in late summer and early autumn the roof surface heats up and cools down markedly over the course of a day.
The same Selçuk University study reports that Konya sees about 103 days a year with frost events (temperature falling to 0 °C), of which about 69 fall in the winter months. The number of days on which the temperature drops below 0 °C and rises above it within the same day is not given, because it does not appear in the sources we compiled; but considering frost approaching a hundred days together with the daily temperature swing, it is clear that the cladding and joints will be tested by water and frost.
Snow load and the effect of pitch
Which snow zone is Konya in?
According to the list in the National Annex of TS EN 1991-1-3 (2007), the Konya provincial center is in Snow Zone II. In Zone II the ground snow load increases with altitude: 0.75 kN/m² up to 700 m, 0.85 at 800 m, 0.95 at 900 m and 1.05 kN/m² at 1000 m. Since Konya is at about 1000 m elevation, the table value for the provincial center is 1.05 kN/m². Because 1 kN/m² corresponds to about 102 kg/m², this is a design limit value on the order of roughly 105 kg/m²; it does not mean that much snow accumulates on a roof every winter. The table note says values should be increased above 1000 m; how to apply this must be learned from the text of the standard and from an engineer.
In the list, districts appear in different zones: Cihanbeyli, Karapınar and Kulu are in Zone I; Akşehir, Beyşehir, Bozkır, Çumra and Ereğli are in Zone II. Because the list reflects the old district structure, the zone of districts established later cannot be read from it. For district notes, see the service areas page. The greatest snow depth measured in Konya in MGM records is 66 cm (February 1945).
How does the snow on the roof change as the pitch increases?
According to the standard, the snow load on a roof is found by multiplying the ground snow load by the roof shape coefficient; exposure and thermal coefficients also come into the calculation. For single- and double-pitched roofs the shape coefficient is 0.8 between 0° and 30°; it decreases linearly between 30° and 60° and is taken as zero at 60° and above. In short, the steeper the pitch, the less snow stays on the roof. However, if there is a snow guard or eaves parapet that prevents the snow from sliding, the coefficient is taken as at least 0.8; that is, adding a snow guard eliminates the load reduction that the pitch provides. Snow accumulation in valleys, at projections and at the foot of tall walls is calculated separately. For terms, see the glossary entries on snow load and roof pitch; for choosing the pitch, see the article how to choose the roof pitch.
Frost, ice dams and falling ice
Water that enters the cladding and joints increases in volume when it freezes; for this reason it is important to choose products with certified frost resistance. For clay tiles, TS EN 539-2 defines how frost resistance is tested; the number of cycles and the acceptance criterion should be learned from the product certificate and the manufacturer.
An ice dam, on the other hand, is related to thermal insulation. According to a guide by PNNL, which is affiliated with the US Department of Energy, when there is snow on the roof, heat escaping from the heated space raises the underside of the cladding above freezing, the snow melts from below, the water refreezes at the cold eaves and an ice “dam” forms; the accumulated water can seep under the cladding. Order of measures: first seal air leaks, then ceiling insulation, then ventilation entering at the eaves and exiting at the ridge. Because the guide's numerical values are given for the US climate, they should not be transferred to Türkiye as they are. For the concept, see the ice dam entry.
A Turkish academic study (Çakıcı, 2018) describes how icicles at the eaves can break off and fall when the air warms, causing damage, and how a metal roof heated by the sun can warm the ice mass from underneath and make it break off more easily. For this reason, a snow guard is evaluated separately on roofs over entrances, walkways and car parks. The sources we compiled contain no Turkish provision making a snow guard mandatory at a particular pitch; therefore we do not say “it is mandatory.” A manufacturer's guide also says that a snow guard is not fall protection and that its placement is determined by pitch and ground snow load.
Thermal movement and wind suction on metal roofs
Metal changes length with temperature: the expansion is the product of the length, the expansion coefficient and the temperature difference. For titanium zinc, manufacturers give 0.022 mm/(m·K); this comes to about 2.2 mm per meter at a 100 K difference. Because sun-exposed metal surfaces can be much hotter than the air, one manufacturer bases its design on the range from −20 °C to +80 °C. For this reason, on standing seam roof systems, the panels are held with fixed and sliding clips; according to the same manufacturer, the standard panel length is limited to 10 m, and for longer ones the manufacturer's engineer should be consulted. It would not be right to give a single millimeter figure for Konya; the result varies with the metal, panel length and installation temperature. For the concept, see the thermal expansion entry.
On a roof, wind creates not only pushing force but also suction (uplift) force, especially at edge, corner and ridge zones. In EN 1991-1-4, a pitched roof surface is divided into zones, and in most of these zones the external pressure coefficients act in the suction direction; separate coefficients are used for local elements such as fasteners and tiles. According to MGM, the fastest daily wind in Konya was measured at 32.4 m/s on 18 April 2012. How many extra fasteners are needed at edges and corners depends on the product and roof geometry; the manufacturer's current installation guide should be consulted. For the concept, see the wind suction entry.
What climate effects mean for the roof
| Climate effect | What it causes on the roof | Point to watch |
|---|---|---|
| Snow load (Zone II) | Vertical load on the structure, accumulation points | Structural calculation, pitch, snow guard effect |
| About 103 days a year with frost events | Freeze damage at joints, ice at the eaves | Product with certified frost resistance, ventilation |
| Daytime temperature swing | Expansion and contraction in metal | Fixed and sliding clips, panel length |
| Wind | Suction force at edges and corners | Fastening, manufacturer's installation guide |
| Cold winter | Heat loss, condensation, ice dam | Thermal insulation, vapor control |
Thermal insulation and condensation
TS 825 defines the maximum permitted heat transmittance values by climate zone; there is a limit value for each region, and the current value is checked at the project stage. In a ventilated (cold) metal roof, warm, humid air from the interior carries vapor out through the cross-section; if the cross-section is not built well, condensation and freezing occur on the cold inner face of the metal, which leads to corrosion and timber rot. A titanium zinc manufacturer lists two measures: a vapor control layer on the inner side of the insulation, or a cavity on the outer side ventilated with outside air. For the layer order, see the article roof insulation layers and vapor barrier.
Before you decide
Article 40 of the Regulation on Zoning for Planned Areas says that roof pitches are determined with the approval of the relevant authority, taking into account the roofing material, the architectural character of the locality and climate conditions; climate also appears as a criterion in the legislation. Before renovating a roof, the following can be asked:
- Have the altitude and snow zone been checked from the design and structural standpoint?
- Is there a current manufacturer document for the cladding's frost resistance, wind fastening and pitch limit?
- Have the snow guard and eaves measures been planned with respect to entrances and pedestrian areas?
- For metal, are the panel length, expansion allowance and clip layout defined?
When choosing the cladding, tile roof systems and standing seam roofs can be evaluated side by side; the roof calculator can be used for a preliminary calculation of area and materials, and Rızaoğlu Çatı can be contacted for an on-site site survey.
FAQ
What snow load is taken into account for roofs in Konya?
According to the National Annex of TS EN 1991-1-3 (2007), the Konya city center is in Snow Zone II, and the tabulated ground snow load for 1000 m is 1.05 kN/m²; this is a design limit value of roughly 105 kg/m². The actual load on the roof varies with pitch, wind and snow accumulation points. The calculation must be made by a licensed engineer, taking the current standard and the altitude into account.
How many days of frost does Konya have per year?
According to a study by Selçuk University using 1975-2006 data, Konya sees about 103 frost days per year, meaning days when the temperature drops to 0 °C, of which about 69 fall in the winter months. This figure may differ in recent years and is not the number of daily freeze-thaw cycles.
Are snow guards mandatory in Konya?
The sources we compiled contain no Turkish provision that makes snow guards mandatory at a given pitch. They are generally considered in areas with heavy snowfall, above entrances, walkways and parking areas, and on slippery claddings. Manufacturers state that a snow guard is not fall protection and that its placement is determined by pitch and snow load.
Can a metal roof be used in Konya?
Manufacturer guides define measures for metal claddings such as an expansion allowance, sliding clips, snow guards, ventilation and vapor control. When these are applied correctly, the climate is not considered a factor that rules out a metal roof on its own. Panel length, pitch and layer arrangement must be determined in the project according to the manufacturer's current installation guide.
Is there a limit value specific to Konya for roof thermal insulation?
TS 825 defines the maximum permitted heat transmittance values by climate zone. Because the standard has been revised, the current table and the value applied to Konya must be checked at the project stage. Insulation thickness is calculated separately according to the material and the roof section.